❄️ Heat Pump & HVAC Thermal Load · EN 12831 & ACCA Manual J Reference

Heat Pump Sizing for 210 m² (2,260 sq ft) — US Sunbelt & Mediterranean (TX/FL/CA/ES/IT)

Thermal heat loss calculation, recommended heat pump capacity (kW, BTU/h & HVAC Tons), SCOP efficiency, and annual electricity consumption.

Recommended Heat Pump10.4 kW35,486 BTU/h (2.96 Tons)
Annual Electricity Usage3,351 kWh/yrDelivers 14,745 kWh Heat (SCOP 4.4)
Savings vs Direct Electric11,394 kWh/yrSpecific Load: 46.8 W/m²
Electrical Circuit (230V)16 A BreakerPeak Compressor Input: 2.89 kW

Thermal & Electrical Specification Table (210 m² / 2,260 sq ft)

Heated Floor Area210 m² (2,260 sq ft)
Climate Zone & Design Outdoor TempUS Sunbelt & Mediterranean (TX/FL/CA/ES/IT)
Building Insulation EnvelopeStandard Double-Glazed Insulation (55 W/m² Base) (46.8 W/m² Peak)
Peak Space Heating Load9.83 kW Thermal
Recommended Heat Pump Output (Incl. DHW)10.4 kW (35,486 BTU/h · 2.96 Tons)
Seasonal Coefficient of Performance (SCOP)4.4 (340%–450% Seasonal Efficiency)
Annual Heat Demand vs Electricity Consumed14,745 kWh Heat → 3,351 kWh Electricity

Frequently Asked Questions

What kW size heat pump do I need for a 210 m² (2260 sq ft) house?

For a 210 m² (2260 sq ft) building with Standard Double-Glazed Insulation (55 W/m² Base) in US Sunbelt & Mediterranean (TX/FL/CA/ES/IT), the peak space heating load is 9.83 kW (46.8 W/m²). Including domestic hot water allowance, a 10.4 kW (35,486 BTU/h / 2.96 Ton) heat pump is recommended.

How many kWh of electricity does a 10.4 kW heat pump use per year?

With a Seasonal Coefficient of Performance (SCOP) of 4.4 over 1500 full-load equivalent heating hours, the heat pump consumes approximately 3,351 kWh of electricity per year to deliver 14,745 kWh of heat — saving 11,394 kWh/year compared to direct electric radiators.